Filter Profile Service
Carlos Rodrigo
A repository of Filter information for the VO.
Grant PID2020-112494GBI00 funded by
Astronomy (7905)Planetary science (616)Earth Obs. (2452)


VATT :The Vatican Advanced Technology Telescope
VATT/VATT :The Vatican Advanced Technology Telescope filtersid:VATT/VATT.a
GaiaXPy base XML file. You can download here the GaiaXPy base XML file for the full VATT/VATT filter set. Please, take a look to the GaiaXPy web page and additional documentation for more information.

VATT/VATT.U_vilnius3428.983439.253435.383020.113815.62437.551281.253.27e-9VATT VATT U Vilnius filter
VATT/VATT.u_sdss3464.533484.603506.202968.793991.66645.261420.283.55e-9VATT VATT u' sdss filter
VATT/VATT.u3568.453584.663627.013072.534068.15570.531628.053.83e-9VATT VATT u filter
VATT/VATT.P_vilnius3760.053763.773792.673479.874028.18254.952202.844.67e-9VATT VATT P Vilnius filter
VATT/VATT.X_vilnius4078.634081.934080.523815.364518.60220.994118.127.42e-9VATT VATT X Vilnius filter
VATT/VATT.b4326.124369.364336.843581.415733.681024.353931.506.3e-9VATT VATT b filter
VATT/VATT.Y_vilnius4644.784649.384639.504256.115154.51290.014203.365.84e-9VATT VATT Y Vilnius filter
VATT/VATT.g_sdss4720.534777.524680.353932.675647.811397.574025.075.42e-9VATT VATT g' sdss filter
VATT/VATT.Z_vilnius5179.275183.755175.464768.525687.45256.813812.834.26e-9VATT VATT Z Vilnius filter
VATT/VATT.v5398.995425.625373.984849.996441.82871.453679.163.78e-9VATT VATT v filter
X
VATT/VATT.v
Filter Description

Filter ID (?) :VATT/VATT.v
Description (?) :VATT v filter
Phot.System (?) :------
Detector Type (?) :Energy counter
Band Name (?) :v
Obs. Facility (?) :VATT
Instrument (?) :------
Comments (?) :------

 
Mathematical properties

Property Calculated Specified Unit
λref (?) : 5398.99 ------- (Angstrom)
λmean (?) : 5425.62 ------- (Angstrom)
λcen (?) : 5380.79 ------- (Angstrom)
λeff (?) : 5373.98 ------- (Angstrom)
λpeak (?) : 5190.00 ------- (Angstrom)
λpivot (?) : 5398.99 ------- (Angstrom)
λphot (?) : 5390.89 ------- (Angstrom)
λmin (?) : 4849.99 ------- (Angstrom)
λmax (?) : 6441.82 ------- (Angstrom)
Weff (?) : 871.45 ------- (Angstrom)
FWHM (?) : 877.38 ------- (Angstrom)
Af/AV (?) : 1.03 ------- ()
Fsun (?) : 186.20 ------- (erg/cm2/s/A)

Transmission

Data file: ascii, VOTable

Reference for filter response: VATT

Transmission components: Filterid:VATT/VATT.v
 

You can download here the GaiaXPy base XML file for the full VATT/VATT filter set.
Please, take a look to GaiaXPy documentation for more information.

- GaiaXPy base XML file.

   
Calibration properties

Vega System
PropertySpecified Calculated Unit
Zero Point (?) : ------- 3.78394e-9(erg/cm2/s/A)
  ------- 3679.16(Jy)
ZP Type (?) : Pogson
PhotCal ID (?) : VATT/VATT.v/Vega
 

AB System
PropertySpecified Calculated Unit
Zero Point (?) : ------- 3.73442e-9(erg/cm2/s/A)
  ------- 3631.00(Jy)
ZP Type (?) : Pogson
PhotCal ID (?) : VATT/VATT.v/AB
 

ST System
PropertySpecified Calculated Unit
Zero Point (?) : ------- 3.631e-9(erg/cm2/s/A)
  ------- 3530.45(Jy)
ZP Type (?) : Pogson
PhotCal ID (?) : VATT/VATT.v/ST
 


Filter added: 2018-03-08 13:10:18
Last update: 2021-07-27 20:43:42
VATT/VATT.V_vilnius5445.245448.295442.355122.305816.20262.283637.843.68e-9VATT VATT V Vilnius filter
VATT/VATT.r_sdss6186.286221.236146.075393.537059.441265.593179.082.49e-9VATT VATT r' sdss filter
VATT/VATT.r6374.066438.576309.955558.658427.881234.253096.352.28e-9VATT VATT r filter
VATT/VATT.S_vilnius6552.176554.276549.176234.166903.34206.462811.671.96e-9VATT VATT S Vilnius filter
VATT/VATT.T_vilnius7158.267161.007155.456809.567550.44229.082721.001.59e-9VATT VATT T Vilnius filter
VATT/VATT.i_sdss7652.587685.187616.286745.138548.071358.702530.491.3e-9VATT VATT i' sdss filter
VATT/VATT.i8077.038116.818038.797242.699056.151480.712394.991.1e-9VATT VATT i filter
VATT/VATT.z_sdss9575.119667.649500.158178.8611000.002631.852149.467.03e-10VATT VATT z' sdss filter
 

Filter Plots (using a common λ range)

(Plot them zoomed to their own λ range)


© SVO,   (SVO Privacy Policy),   10970 filters available,   Last update: 2023-06-19
 
If your research benefits from the use of the SVO Filter Profile Service, we would appreciate if you could include the following acknowledgement in your publication:

This research has made use of the SVO Filter Profile Service "Carlos Rodrigo", funded by MCIN/AEI/10.13039/501100011033/ through grant PID2020-112949GB-I00

and we would appreciate if you could include the following references in your publication: