Filter Profile Service
Carlos Rodrigo
A repository of Filter information for the VO.
Grant PID2020-112494GBI00 funded by
Astronomy (7905)Planetary science (616)Earth Obs. (2452)


Sentinel :ESA is developing a series of next-generation Earth observation missions, on behalf of the joint ESA/European Commission initiative GMES (Global Monitoring for Environment and Security).
Sentinel/MSI :The SENTINEL-2 Multispectral Instrument (MSI) samples 13 spectral bands: four bands at 10 metres, six bands at 20 metres and three bands at 60 metres spatial resolution.id:Sentinel/MSI.a

Sentinel/MSI.B01-B4421.034422.344425.964117.634559.51192.564090.936.27e-9SentinelMSISentinel2 MSI B01-B normalized SRF
Sentinel/MSI.B01-A4426.184427.374430.964292.284560.00176.664114.136.3e-9SentinelMSISentinel2 MSI B01-A normalized SRF
Sentinel/MSI.B02-B4910.024921.334899.764384.625314.82608.323931.964.89e-9SentinelMSISentinel2 MSI B02-B normalized SRF
Sentinel/MSI.B02-A4913.254924.414903.234390.005313.71583.143929.654.88e-9SentinelMSISentinel2 MSI B02-A normalized SRF
Sentinel/MSI.B03-B5586.595589.505583.745365.985817.67326.673550.973.41e-9SentinelMSISentinel2 MSI B03-B normalized SRF
Sentinel/MSI.B03-A5595.695598.545592.915380.005824.88310.123545.323.39e-9SentinelMSISentinel2 MSI B03-A normalized SRF
Sentinel/MSI.B04-A6644.296646.216646.056463.516837.34282.522817.061.91e-9SentinelMSISentinel2 MSI B04-A normalized SRF
Sentinel/MSI.B04-B6647.586649.386649.276462.256838.82287.862825.461.92e-9SentinelMSISentinel2 MSI B04-B normalized SRF
Sentinel/MSI.B05-B7037.937038.317037.476940.007137.61137.992774.941.68e-9SentinelMSISentinel2 MSI B05-B normalized SRF
Sentinel/MSI.B05-A7040.857041.227040.406950.007139.25134.422773.301.68e-9SentinelMSISentinel2 MSI B05-A normalized SRF
Sentinel/MSI.B06-B7390.967391.297390.567300.007479.98132.012623.471.44e-9SentinelMSISentinel2 MSI B06-B normalized SRF
Sentinel/MSI.B06-A7404.517404.847404.117311.577490.00132.012617.991.43e-9SentinelMSISentinel2 MSI B06-A normalized SRF
Sentinel/MSI.B07-B7796.567797.247795.837660.007932.82189.332458.131.21e-9SentinelMSISentinel2 MSI B07-B normalized SRF
Sentinel/MSI.B07-A7826.897827.557826.307700.007967.82173.682446.511.2e-9SentinelMSISentinel2 MSI B07-A normalized SRF
Sentinel/MSI.B08-A8308.338327.958292.767742.839064.87848.032318.661.01e-9SentinelMSISentinel2 MSI B08-A normalized SRF
Sentinel/MSI.B08-B8309.908329.478294.477755.119065.56842.622318.821.01e-9SentinelMSISentinel2 MSI B08-B normalized SRF
Sentinel/MSI.B08a-B8639.118639.808638.998485.808794.09206.222224.488.94e-10SentinelMSISentinel2 MSI B08a-B normalized SRF
Sentinel/MSI.B08a-A8646.438647.118646.248486.938800.64205.942223.828.92e-10SentinelMSISentinel2 MSI B08a-A normalized SRF
Sentinel/MSI.B09-B9431.239431.779429.099300.009567.14187.382279.867.68e-10SentinelMSISentinel2 MSI B09-B normalized SRF
Sentinel/MSI.B09-A9450.019450.559446.689320.009580.00191.012240.447.52e-10SentinelMSISentinel2 MSI B09-A normalized SRF
Sentinel/MSI.B10-A13733.7913734.6213732.6413531.8313944.50283.031332.712.12e-10SentinelMSISentinel2 MSI B10-A normalized SRF
Sentinel/MSI.B10-B13767.9513768.8313766.7513557.9913977.54290.421327.552.1e-10SentinelMSISentinel2 MSI B10-B normalized SRF
Sentinel/MSI.B11-B16097.2916104.2016088.8915536.6116676.70913.371032.181.19e-10SentinelMSISentinel2 MSI B11-B normalized SRF
Sentinel/MSI.B11-A16130.1716136.5916122.6215563.9016688.29877.501029.311.19e-10SentinelMSISentinel2 MSI B11-A normalized SRF
Sentinel/MSI.B12-B21836.8921856.9921807.8720728.2523007.141775.89637.994.01e-11SentinelMSISentinel2 MSI B12-B normalized SRF
X
Sentinel/MSI.B12-B
Filter Description

Filter ID (?) :Sentinel/MSI.B12-B
Description (?) :Sentinel2 MSI B12-B normalized SRF
Phot.System (?) :MSI
Detector Type (?) :Energy counter
Band Name (?) :------
Obs. Facility (?) :Sentinel
Instrument (?) :MSI
Comments (?) :------

 
Mathematical properties

Property Calculated Specified Unit
λref (?) : 21836.89 ------- (Angstrom)
λmean (?) : 21856.99 ------- (Angstrom)
λcen (?) : 21844.05 ------- (Angstrom)
λeff (?) : 21807.87 ------- (Angstrom)
λpeak (?) : 22600.00 ------- (Angstrom)
λpivot (?) : 21836.89 ------- (Angstrom)
λphot (?) : 21821.34 ------- (Angstrom)
λmin (?) : 20728.25 ------- (Angstrom)
λmax (?) : 23007.14 ------- (Angstrom)
Weff (?) : 1775.89 ------- (Angstrom)
FWHM (?) : 1834.31 ------- (Angstrom)
Af/AV (?) : 0.123 ------- ()
Fsun (?) : 8.44 ------- (erg/cm2/s/A)

Transmission

Data file: ascii, VOTable

Reference for filter response: Sentinel2

Transmission components: Filter + Instrumentid:Sentinel/MSI.B12-B

   
Calibration properties

Vega System
PropertySpecified Calculated Unit
Zero Point (?) : ------- 4.011e-11(erg/cm2/s/A)
  ------- 637.99(Jy)
PhotCal ID (?) : Sentinel/MSI.B12-B/Vega
 

AB System
PropertySpecified Calculated Unit
Zero Point (?) : ------- 2.28279e-10(erg/cm2/s/A)
  ------- 3631.00(Jy)
PhotCal ID (?) : Sentinel/MSI.B12-B/AB
 

ST System
PropertySpecified Calculated Unit
Zero Point (?) : ------- 3.631e-9(erg/cm2/s/A)
  ------- 57754.68(Jy)
PhotCal ID (?) : Sentinel/MSI.B12-B/ST
 


Filter added: 2020-08-28 22:18:52
Last update: 2021-07-27 20:33:53
Sentinel/MSI.B12-A22005.9122023.6621981.9320869.9723162.741601.16628.873.89e-11SentinelMSISentinel2 MSI B12-A normalized SRF
 

Filter Plots (using a common λ range)

(Plot them zoomed to their own λ range)



© SVO,   (SVO Privacy Policy),   10970 filters available,   Last update: 2023-06-19
 
If your research benefits from the use of the SVO Filter Profile Service, we would appreciate if you could include the following acknowledgement in your publication:

This research has made use of the SVO Filter Profile Service "Carlos Rodrigo", funded by MCIN/AEI/10.13039/501100011033/ through grant PID2020-112949GB-I00

and we would appreciate if you could include the following references in your publication: