NOAO/NEWFIRM.1056nm10566.710566.710554105818.92016.7Gemini,CTIONEWFIRMNEWFIRM 1056nm filter, raw data
NOAO/NEWFIRM.1063nm10633.910633.910621106489.21991.7Gemini,CTIONEWFIRMNEWFIRM 1063nm filter, raw data
NOAO/NEWFIRM.JX12511.512428.011393136121665.31559.1Gemini,CTIONEWFIRMNEWFIRM JX filter, room temp (298K), Aura, measured at center
X
NOAO/NEWFIRM.JX
Filter Description

Filter ID (?) :NOAO/NEWFIRM.JX
Description (?) :NEWFIRM JX filter, room temp (298K), Aura, measured at center
Phot.System (?) :NEWFIRM
Detector Type (?) :Energy counter
Band Name (?) :------
Obs. Facility (?) :Gemini,CTIO
Instrument (?) :NEWFIRM
Comments (?) :------

 
Mathematical properties

Property Calculated Specified Unit
λmean (?) : 12511.55 ------- (Angstrom)
λcen (?) : 12493.33 ------- (Angstrom)
λeff (?) : 12428.01 ------- (Angstrom)
λpeak (?) : 13117.00 ------- (Angstrom)
λpivot (?) : 12476.96 ------- (Angstrom)
λphot (?) : 12451.09 ------- (Angstrom)
λmin (?) : 11393.26 ------- (Angstrom)
λmax (?) : 13611.70 ------- (Angstrom)
Weff (?) : 1665.25 ------- (Angstrom)
FWHM (?) : 1788.61 ------- (Angstrom)
Af/AV (?) : 0.30 ------- ()

Transmission curve

Data file: ascii, VOTable

Reference for filter response: NEWFIRM

   
Calibration properties

Vega System
PropertySpecified Calculated Unit
Zero Point (?) : ------- 3.026e-10(erg/cm2/s/A)
  ------- 1559.06(Jy)
ZP Type (?) : Pogson
PhotCal ID (?) : NOAO/NEWFIRM.JX/Vega
 

AB System
PropertySpecified Calculated Unit
Zero Point (?) : ------- 7.048e-10(erg/cm2/s/A)
  ------- 3631.00(Jy)
ZP Type (?) : Pogson
PhotCal ID (?) : NOAO/NEWFIRM.JX/AB
 

ST System
PropertySpecified Calculated Unit
Zero Point (?) : ------- 3.631e-9(erg/cm2/s/A)
  ------- 18707.20(Jy)
ZP Type (?) : Pogson
PhotCal ID (?) : NOAO/NEWFIRM.JX/ST
 


Filter added: 2014-05-31 18:22:29
Last update: 2018-03-21 17:34:01
NOAO/NEWFIRM.HX16319.116151.114575181052976.31044.7Gemini,CTIONEWFIRMNEWFIRM HX filter, room temp (298K), measured at center
NOAO/NEWFIRM.KX21451.721290.019462234803083.3677.1Gemini,CTIONEWFIRMNEWFIRM KX filter, room temp (298K), measured at center
 

Filter Plots

© SVO,   5060 filters available,   Last update: 2019-09-30
 
If your research benefits from the use of the SVO Filter Profile Service, we would appreciate if you could include the following acknowledgement in your publication:

This research has made use of the SVO Filter Profile Service (http://svo2.cab.inta-csic.es/theory/fps/) supported from the Spanish MINECO through grant AYA2017-84089

and we would appreciate if you could include the following references in your publication: