Filter Profile Service
A repository of Filter information for the VO

NOAO/NEWFIRM.1056nm10566.710566.710554105818.92016.7Gemini,CTIONEWFIRMNEWFIRM 1056nm filter, raw data
X
NOAO/NEWFIRM.1056nm
Filter Description

Filter ID (?) :NOAO/NEWFIRM.1056nm
Description (?) :NEWFIRM 1056nm filter, raw data
Phot.System (?) :NEWFIRM
Detector Type (?) :Energy counter
Band Name (?) :------
Obs. Facility (?) :Gemini,CTIO
Instrument (?) :NEWFIRM
Comments (?) :------

 
Mathematical properties

Property Calculated Specified Unit
λmean (?) : 10566.72 ------- (Angstrom)
λcen (?) : 10566.52 ------- (Angstrom)
λeff (?) : 10566.72 ------- (Angstrom)
λpeak (?) : 10565.50 ------- (Angstrom)
λpivot (?) : 10566.72 ------- (Angstrom)
λphot (?) : 10566.72 ------- (Angstrom)
λmin (?) : 10553.89 ------- (Angstrom)
λmax (?) : 10580.84 ------- (Angstrom)
Weff (?) : 8.88 ------- (Angstrom)
FWHM (?) : 7.98 ------- (Angstrom)
Af/AV (?) : 0.39 ------- ()

Transmission curve

Data file: ascii, VOTable

Reference for filter response: NEWFIRM

   
Calibration properties

Vega System
PropertySpecified Calculated Unit
Zero Point (?) : ------- 5.415e-10(erg/cm2/s/A)
  ------- 2016.72(Jy)
ZP Type (?) : Pogson
PhotCal ID (?) : NOAO/NEWFIRM.1056nm/Vega
 

AB System
PropertySpecified Calculated Unit
Zero Point (?) : ------- 9.749e-10(erg/cm2/s/A)
  ------- 3631.00(Jy)
ZP Type (?) : Pogson
PhotCal ID (?) : NOAO/NEWFIRM.1056nm/AB
 

ST System
PropertySpecified Calculated Unit
Zero Point (?) : ------- 3.631e-9(erg/cm2/s/A)
  ------- 13523.41(Jy)
ZP Type (?) : Pogson
PhotCal ID (?) : NOAO/NEWFIRM.1056nm/ST
 


Filter added: 2014-05-31 18:17:40
Last update: 2018-03-21 17:34:01
NOAO/NEWFIRM.1063nm10633.910633.910621106489.21991.7Gemini,CTIONEWFIRMNEWFIRM 1063nm filter, raw data
NOAO/NEWFIRM.JX12511.512428.011393136121665.31559.1Gemini,CTIONEWFIRMNEWFIRM JX filter, room temp (298K), Aura, measured at center
NOAO/NEWFIRM.HX16319.116151.114575181052976.31044.7Gemini,CTIONEWFIRMNEWFIRM HX filter, room temp (298K), measured at center
NOAO/NEWFIRM.KX21451.721290.019462234803083.3677.1Gemini,CTIONEWFIRMNEWFIRM KX filter, room temp (298K), measured at center
 

Filter Plots

© SVO,   5060 filters available,   Last update: 2019-09-30
 
If your research benefits from the use of the SVO Filter Profile Service, we would appreciate if you could include the following acknowledgement in your publication:

This research has made use of the SVO Filter Profile Service (http://svo2.cab.inta-csic.es/theory/fps/) supported from the Spanish MINECO through grant AYA2017-84089

and we would appreciate if you could include the following references in your publication: