Filter Profile Service
A repository of Filter information for the VO

HST/STIS_FUV.F25LYA1248.71369.51150151299.759.9HSTSTISF25LYA filter for HST STIS_FUV, with no grating
HST/STIS_FUV.F25LYA_G140L1250.81359.011501522116.764.0HSTSTISF25LYA filter for HST STIS_FUV, with G140L grating
HST/STIS_FUV.F25LYA_G140M1251.31356.111501512112.262.9HSTSTISF25LYA filter for HST STIS_FUV, with G140M grating
HST/STIS_FUV.25MAMA_G140M1366.61443.311501742278.7263.9HSTSTIS25MAMA filter for HST STIS_FUV, with G140M grating
HST/STIS_FUV.F25ND3_G140M1369.01441.711501742278.0269.1HSTSTISF25ND3 filter for HST STIS_FUV, with G140M grating
HST/STIS_FUV.25MAMA_G140L1370.11446.011501725298.0271.2HSTSTIS25MAMA filter for HST STIS_FUV, with G140L grating
HST/STIS_FUV.F25ND3_G140L1372.81444.711501725296.0276.6HSTSTISF25ND3 filter for HST STIS_FUV, with G140L grating
HST/STIS_FUV.F25ND5_G140M1376.01452.511501742282.5276.4HSTSTISF25ND5 filter for HST STIS_FUV, with G140M grating
HST/STIS_FUV.F25ND5_G140L1380.01455.311501725302.8284.2HSTSTISF25ND5 filter for HST STIS_FUV, with G140L grating
HST/STIS_FUV.F25NDQ2_G140M1390.81458.611601742312.1301.4HSTSTISF25NDQ2 filter for HST STIS_FUV, with G140M grating
HST/STIS_FUV.25MAMA1393.01477.211501876347.9294.3HSTSTIS25MAMA filter for HST STIS_FUV, with no grating
HST/STIS_FUV.F25ND31393.31472.511501867349.5297.7HSTSTISF25ND3 filter for HST STIS_FUV, with no grating
HST/STIS_FUV.F25NDQ3_G140M1394.21460.511601742329.6307.5HSTSTISF25NDQ3 filter for HST STIS_FUV, with G140M grating
HST/STIS_FUV.F25NDQ2_G140L1394.91461.111601726332.0309.4HSTSTISF25NDQ2 filter for HST STIS_FUV, with G140L grating
HST/STIS_FUV.F25NDQ3_G140L1398.31463.011601726348.0315.6HSTSTISF25NDQ3 filter for HST STIS_FUV, with G140L grating
HST/STIS_FUV.F25NDQ1_G140M1400.21461.811501742320.9317.3HSTSTISF25NDQ1 filter for HST STIS_FUV, with G140M grating
HST/STIS_FUV.F25NDQ1_G140L1404.11464.211501726329.6325.1HSTSTISF25NDQ1 filter for HST STIS_FUV, with G140L grating
HST/STIS_FUV.F25ND51404.31486.411501868356.8309.3HSTSTISF25ND5 filter for HST STIS_FUV, with no grating
HST/STIS_FUV.F25NDQ4_G140M1415.11469.011501742342.9341.1HSTSTISF25NDQ4 filter for HST STIS_FUV, with G140M grating
HST/STIS_FUV.F25NDQ4_G140L1418.91471.011501725346.8348.6HSTSTISF25NDQ4 filter for HST STIS_FUV, with G140L grating
HST/STIS_FUV.F25NDQ21423.11494.411601887407.6337.6HSTSTISF25NDQ2 filter for HST STIS_FUV, with no grating
HST/STIS_FUV.F25NDQ31426.41495.711601890416.5343.3HSTSTISF25NDQ3 filter for HST STIS_FUV, with no grating
HST/STIS_FUV.F25NDQ11434.31498.111501891402.5354.7HSTSTISF25NDQ1 filter for HST STIS_FUV, with no grating
HST/STIS_FUV.F25SRF2_G140M1435.21457.412461742225.4387.5HSTSTISF25SRF2 filter for HST STIS_FUV, with G140M grating
HST/STIS_FUV.F25SRF2_G140L1437.81459.512461725235.1392.5HSTSTISF25SRF2 filter for HST STIS_FUV, with G140L grating
HST/STIS_FUV.F25NDQ41451.91505.911501895395.2380.4HSTSTISF25NDQ4 filter for HST STIS_FUV, with no grating
HST/STIS_FUV.F25SRF21470.21491.712441887288.3422.1HSTSTISF25SRF2 filter for HST STIS_FUV, with no grating
HST/STIS_FUV.F25QTZ_G140L1566.11565.514521725169.1548.9HSTSTISF25QTZ filter for HST STIS_FUV, with G140L grating
HST/STIS_FUV.F25QTZ_G140M1570.01569.114511742168.3550.0HSTSTISF25QTZ filter for HST STIS_FUV, with G140M grating
X
HST/STIS_FUV.F25QTZ_G140M
Filter Description

Filter ID (?) :HST/STIS_FUV.F25QTZ_G140M
Description (?) :F25QTZ filter for HST STIS_FUV, with G140M grating
Phot.System (?) :------
Detector Type (?) :Photon counter
Band Name (?) :------
Obs. Facility (?) :HST
Instrument (?) :STIS
Comments (?) :Response calculated using the stsynphot python package by STScI. In particular, function stsynphot.bp("stis,fuvmama,f25qtz,g140m"). Please, take a look to stsynphot documentation and HST instrument documentation

 
Mathematical properties

Property Calculated Specified Unit
λmean (?) : 1570.04 ------- (Angstrom)
λcen (?) : 1526.88 ------- (Angstrom)
λeff (?) : 1569.11 ------- (Angstrom)
λpeak (?) : 1486.00 ------- (Angstrom)
λpivot (?) : 1564.44 ------- (Angstrom)
λphot (?) : 1572.85 ------- (Angstrom)
λmin (?) : 1451.33 ------- (Angstrom)
λmax (?) : 1742.25 ------- (Angstrom)
Weff (?) : 168.33 ------- (Angstrom)
FWHM (?) : 133.01 ------- (Angstrom)
Af/AV (?) : 2.59 ------- ()

Transmission curve

Data file: ascii, VOTable

Reference for filter response: stsynphot documentation

   
Calibration properties

Vega System
PropertySpecified Calculated Unit
Zero Point (?) : ------- 6.697e-9(erg/cm2/s/A)
  ------- 550.00(Jy)
PhotCal ID (?) : HST/STIS_FUV.F25QTZ_G140M/Vega
 

AB System
PropertySpecified Calculated Unit
Zero Point (?) : ------- 4.421e-8(erg/cm2/s/A)
  ------- 3631.00(Jy)
PhotCal ID (?) : HST/STIS_FUV.F25QTZ_G140M/AB
 

ST System
PropertySpecified Calculated Unit
Zero Point (?) : ------- 3.631e-9(erg/cm2/s/A)
  ------- 298.20(Jy)
PhotCal ID (?) : HST/STIS_FUV.F25QTZ_G140M/ST
 


Filter added: 2019-07-16 12:15:03
Last update: 2019-09-25 12:36:45
HST/STIS_FUV.F25QTZ1605.41602.714521917226.5569.0HSTSTISF25QTZ filter for HST STIS_FUV, with no grating
 

Filter Plots (using a common λ range)

(Plot them zoomed to their own λ range)



© SVO,   5065 filters available,   Last update: 2019-11-30
 
If your research benefits from the use of the SVO Filter Profile Service, we would appreciate if you could include the following acknowledgement in your publication:

This research has made use of the SVO Filter Profile Service (http://svo2.cab.inta-csic.es/theory/fps/) supported from the Spanish MINECO through grant AYA2017-84089

and we would appreciate if you could include the following references in your publication: